
Technical advantages:
one . Double eyelid surgery design is consistent with surgery It is found that the key of double eyelid surgery is to control the relationship between the height of tarsal plate and double eyelid skin. Traditional surgical methods may cause certain errors in the width of the double eyelid line design. Combining with microscopic technology, it can effectively reduce the height error between the incision line and the tarsal plate suture. In addition, the depth of the incision is uniform to reduce the formation of surgical scars and achieve better results after surgery!

two No error in orbicularis oculi muscle separation The thickness, shape and tension of orbicularis oculi muscle have a great impact on the postoperative effect. Using a microscope, we can see the muscle fibers and the structure of the upper and lower layers of the muscle more clearly than the normal naked eye, which makes it easier to separate the muscle, accurately cut the muscle volume, and reduce the complications of tissue damage and perforation of the eyelid plate and eyelid conjunctiva. At the same time, the edge of muscle resection is neat, which reduces the injury, postoperative reaction and scar reaction.

three More accurate handling of orbital fat : For those with swollen upper eyelid, it is necessary to properly remove the excess fat in the orbital septum. Under the microscope, this operation can more * * remove an appropriate amount of orbital fat under a small incision in the orbital septum, * * greatly reduce postoperative complications, and achieve ideal results!

four enlarge ten times : Suture * thin suture parameters 0/10 , approximately equal to 0.01mm . That is, the 1/4 After the double eyelid surgery is completed, it is necessary to operate under the microscope to grasp the needle insertion position more clearly and accurately, so that the tissue width and depth on both sides of the wound edge are consistent when sewing the wound, the wound edge is well aligned, the tension is moderate, the needle insertion depth is consistent, and the suture damage is reduced. At the same time, the needle body can be clearly seen under the microscope, which sneaks under the skin and in front of the tarsal plate, avoiding peeling through the skin and conjunctiva. At the same time, the suture needle can be reduced and the route of the suture needle can be changed, causing little tissue damage and scar. Moreover, the suture knot is easy to be buried under the skin, which also shortens the operation time.

Technical features:
one Germany imported surgical microscope damage system;
two . Completely solve the coordination relationship between muscle strength and other organizations in an all-round way;
three 、 **** Avoid periocular vascular network
four . Open and close eyes without scar, fast recovery .